• Geophysical Equipment Resistivity and IP Meter for Groundwater Detector Underground Water Finder Induced Polarization Equipment
  • Geophysical Equipment Resistivity and IP Meter for Groundwater Detector Underground Water Finder Induced Polarization Equipment
  • Geophysical Equipment Resistivity and IP Meter for Groundwater Detector Underground Water Finder Induced Polarization Equipment
  • Geophysical Equipment Resistivity and IP Meter for Groundwater Detector Underground Water Finder Induced Polarization Equipment
  • Geophysical Equipment Resistivity and IP Meter for Groundwater Detector Underground Water Finder Induced Polarization Equipment
  • Geophysical Equipment Resistivity and IP Meter for Groundwater Detector Underground Water Finder Induced Polarization Equipment

Geophysical Equipment Resistivity and IP Meter for Groundwater Detector Underground Water Finder Induced Polarization Equipment

After-sales Service: Geophysical Equipment
Warranty: Geophysical Equipment
Receiving Voltage Channel: +-32V(24 Bita/D)
Input Impedance: >50mΩ
Apparent Polarization Accuracy: +-1%& +-1character
Sp Compensation Range: +-10V
Customization:
Gold Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
DUK-2A geophysical equipment
Current Channel
6A(24bita/D)
Transmitting Maximium Power
7200W
Maximium Supply Voltage
+-1200V
Maximium Supply Current
+-6A
Supply Current Width
1~60s, Duty Rate 1:1 Other
Power Supply
Builtin 7.4V4ah
Transport Package
Wooden & Aluminium Case
Specification
ISO9001
Trademark
Gold
Origin
Chongqing, China
Production Capacity
100 Sets/Month

Product Description

Geophysical Resistivity & IP Instrument for Groundwater detector, Underground Water Finder
                                                                                         Geophysical Equipment Resistivity and IP Meter for Groundwater Detector Underground Water Finder Induced Polarization Equipment



 

Application:  
1. Water resources, metal and nonmetal mineral resources detection
2. City geophysical exploration, railway and bridge inspection 
3. Hydrology and engineering geology as inspecting dam base and flood protection levee for incipient faults
4. Geothermal prospecting

Function:   
1. 1D resistivity sounding
2. 1D induced polarization sounding
3. 2D/3D resistivity imaging
3. 2D induced polarization imaging

System composition:
Whole system takes WDA-1 as control unit, can accomplish centralized 2D multi-electrode resistivity survey with WDZJ-4 multi-electrode converter, centralized multi-electrode survey cable and electrodes; also can accomplish Distributed 2D/3D multi-electrode resistivity survey and 2D multi-electrode Res & IP survey with distributed multi-electrode survey cable and electrodes.
                                                                        Geophysical Equipment Resistivity and IP Meter for Groundwater Detector Underground Water Finder Induced Polarization Equipment


WGMD-9 system configuration table:
Function
System
System model Host machine Converter DC high voltage power Cable & Electrode
Centralized 2D multi-electrode Res Survey  
WGMD-9
 
WDA-1
WDZJ-4/WDZJ-120  
External
Centralized cable and electrodes
Distributed 2D/3D multi-electrode Res survey  
WGMD-9A
 
WDA-1
 
N/M
 
External
Distributed multi-electrode Res survey cable and electrodes
Distributed 2D multi-electrode Res & IP survey  
WGMD-9B
 
WDA-1
 
N/M
 
External
Distributed multi-electrode Res & IP survey cable and electrodes

Technical specification (Centralized system):
  WDA-1 control and survey unit
Receiving part
1. voltage channel: ±32V(24 bitA/D)
accuracy: as Vp≥5mV, ±0.2% ±1 character
as 0.1mV≤Vp<5mV, ±1% ±1 character
2. Input impedance: >50MΩ
3. Apparent polarization accuracy: ±1%±1character
4. SP compensation range: ±10V
5. Current channel: 6A(24bitA/D)
measurement accuracy: as Ip≥5mA, ±0.2% ±1character
as 0.1mA≤Ip<5mA, ±1% ±1character
6. As for 50Hz industrial interface(common and different mode)depression is better than 80dB
Transmitter part
1. maximium power: 7200W
2. maximium supply voltage: ±1200V
3. maximium supply current: ±6A
4. supply current width :1~60s, duty rate 1:1
Other
1. working temperature: -10ºC~+50ºC,95%RH
2. storge temperature: -20ºC~+60ºC
3. power supply: builtin 7.4V4Ah(or outside 12V), lasting for 20h
4. main unit port: A, B, M, N, DC high voltage, outside battery, 2 cable port, RS-232, blue tooth
5. weight: ≤4kg
6. size : 270mm×246mm×123mm
Pocket PC
1. Windos Mobile 5.0 system, 624MHz, 640×480true color, 128MB Flash ROM / 64MB SDRAM,512MB CF card, blue
tooth, infrared, serial port, 2 rechargeable batteries, with Word, Excl.
 
  WDZJ-4  Electrode converter
Max electrode connected: 60/unit
Insulation impedance: ≥500MΩ
Max working voltage: 500VDC
Max working current: 2.5ADC
Power supply: Internal 7.4V 4AH rechargeable lithium battery, last for continuously 25 hours work
Working temperature: -10°C~+50°C
Dimension: 340mm×295mm×152mm
Weight: 5.8kg
 
    Centralized 2D Multi-electrode resistivity cable (optional)
1. 32 cores, diameter: Φ6mm.
2. Connectable cable quantity for each converter: 2 pcs (30 channels/pc), can be customized.
3. Channel interval: 5m/10m
4. Maximum working voltage: 450V
5. Maximum working current: 3A
6. Cable insulativity: ≥500MΩ/500V between any two cores.
 
    Centralized 2D Multi-electrode resistivity electrode
1. Copper electrode: Φ12mm×280mm, with connector.
2. Quantity: acquired by customer.

Technical specification (Distributed system):
    WDA-1 control and survey unit    
Same detail as above.
 Geophysical Equipment Resistivity and IP Meter for Groundwater Detector Underground Water Finder Induced Polarization Equipment
    Distributed 2D/3D Multi-electrode resistivity & 2D induced polarization switchable cable (optional)
1. Wide-temperature polyurethane cover, diameter: Φ8mm
2. Channel quantity: 10 channels/pc
3. Channel interval: 1-10m (can be customized between range)
4. Switch dimension: Φ30mm×100mm
5. Maximum working voltage: 800V
5. Maximum working current: 3A
6. Cable insulativity: ≥1000MΩ/1000V between A,B pole supply core and A,B core between other low voltage cores; ≥500MΩ/500V between low voltage cores
7. Working temperature: -20ºC~+70ºC
 
Geophysical Equipment Resistivity and IP Meter for Groundwater Detector Underground Water Finder Induced Polarization Equipment
    Distributed 2D/3D Multi-electrode resistivity & 2D induced polarization survey electrode (optional)

1. Steel electrode: Φ10mm×280mm, with steel connecting spring .
2. Quantity: acquired by customer.

Multiplex Electrode (60120 channels) Resistivity Meter Tomograph  Resistivity Imaging, Ert Electric Resistance Tomograph for Underground Water Finder

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Year of Establishment
2009-09-11
Plant Area
377 square meters