• 30m-500m Ruler Water Well Level Meter Electronic Dipping Tapes Flat Tape Water Level Meters
  • 30m-500m Ruler Water Well Level Meter Electronic Dipping Tapes Flat Tape Water Level Meters
  • 30m-500m Ruler Water Well Level Meter Electronic Dipping Tapes Flat Tape Water Level Meters
  • 30m-500m Ruler Water Well Level Meter Electronic Dipping Tapes Flat Tape Water Level Meters
  • 30m-500m Ruler Water Well Level Meter Electronic Dipping Tapes Flat Tape Water Level Meters
  • 30m-500m Ruler Water Well Level Meter Electronic Dipping Tapes Flat Tape Water Level Meters

30m-500m Ruler Water Well Level Meter Electronic Dipping Tapes Flat Tape Water Level Meters

After-sales Service: Longtime Technical Support
Warranty: 1 Year
Range: 0-500m
High Accuracy: 1mm
Power Supply: 9V
Usage: Water Hole/Drilling Hole
Customization:
Gold Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GYGD
Transport Package
Carton Box
Specification
CE/ISO/FCC
Trademark
GOLD
Origin
China
HS Code
90151000
Production Capacity
100 PCS Per Month

Product Description

30m-500m Ruler Water Well Level Meter Electronic Dipping Tapes Flat Tape Water Level Meters30m-500m Ruler Water Well Level Meter Electronic Dipping Tapes Flat Tape Water Level Meters

We are provide a range of "reel and tape" level and interface meters and measurement instruments. These are ideal for measurement of groundwater levels, 

These high quality instruments include stainless steel interface probes and millimetre marked tapes which are accurate to within EC Class II standard.

Ruler water level is one of the most accurate tool for measuring the water level for measuring wells, drilling and water pipes in the water level, particularly suitable for artificial dam seepage line patrol hydropower project in the groundwater level observations and embankment dam body inspection. During the construction of the instrument can be used also as a long-term safety monitoring works with, in line with earth-rock dam safety monitoring technical specifications.

30m-500m Ruler Water Well Level Meter Electronic Dipping Tapes Flat Tape Water Level Meters
Application

1) soil moisture sensors are widely used in agricultural irrigation systems, soil moisture monitoring, hydrological monitoring and other aspects of water conservation, and the number of mining and its long-distance transmission equipment which may constitute a telemetry system. 
2) For example, when the soil is arid, remote alarm system, while the control system automatically switches the pump and valve control, to automate irrigation. 
3) When combined with some additional sensors, you can also calculate the evaporation of soil moisture and crop water needed parameters.
30m-500m Ruler Water Well Level Meter Electronic Dipping Tapes Flat Tape Water Level Meters


30m-500m Ruler Water Well Level Meter Electronic Dipping Tapes Flat Tape Water Level Meters
30m-500m Ruler Water Well Level Meter Electronic Dipping Tapes Flat Tape Water Level Meters
Use method


1, when tested, loosen spools behind only tighten the screws, press the power button (power indicator light), the probe into the water pipe, holding ruler cable, allowing the probe to move slowly toward the next
2, when the probe contacts come into contact with water, the receiving system sounder will emit a continuous beep, then read out the ruler cable in the depths of the nozzle at a depth dimension, that is, the water table distance from the nozzle
3, if the measurement noise is relatively large environments hear a beep, indicating the peak could be replaced, as long as the selector switch on the instrument panel can be allocated to the voltage block, measurement method as above, when the accuracy of measurement at this time measured with the same precision sound.
Users reading test must note two points:
After A, when the probe contacts come into contact with the water, the sound will sound or voltmeter will indicate immediately, you should slowly ruler retractable cable so carefully to find the pronunciation or indicate the exact position of the moment reads the depth dimension of the aperture pitch.
B, the accuracy of the readings, decided to promptly determine peak song or directions starting position


Maintain

1, due to the limited battery capacity, when the measurement is completed, you should immediately turn off the power switch, do not forget!
2, you must probe and ruler measuring cables, etc., wipe clean after, and the ruler cables neatly wound on spools, and then placed in the bin.
3, the probe sealing work requirements, prohibit demolition, to avoid damage.
4, the probe found faulty, please send me the factory for repair in a timely manner.
5, the ruler should not bend the cable, especially near the ends of the probe, so as not to damage and breakage.
6, the probe should be gently, avoid severe shock.
7.The instrument should be stored at a temperature of -10 ºC ~ + 40 ºC, humidity less than 80% of non-corrosive gases under dry and ventilated ro


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Year of Establishment
2009-09-11
Plant Area
377 square meters