• Geophysical Surveys Electrical Resistivity Induced Polarization Meter Subsurface Water Detection Instrument Geo Ves Mineral Deposits Equipment
  • Geophysical Surveys Electrical Resistivity Induced Polarization Meter Subsurface Water Detection Instrument Geo Ves Mineral Deposits Equipment
  • Geophysical Surveys Electrical Resistivity Induced Polarization Meter Subsurface Water Detection Instrument Geo Ves Mineral Deposits Equipment
  • Geophysical Surveys Electrical Resistivity Induced Polarization Meter Subsurface Water Detection Instrument Geo Ves Mineral Deposits Equipment
  • Geophysical Surveys Electrical Resistivity Induced Polarization Meter Subsurface Water Detection Instrument Geo Ves Mineral Deposits Equipment
  • Geophysical Surveys Electrical Resistivity Induced Polarization Meter Subsurface Water Detection Instrument Geo Ves Mineral Deposits Equipment

Geophysical Surveys Electrical Resistivity Induced Polarization Meter Subsurface Water Detection Instrument Geo Ves Mineral Deposits Equipment

After-sales Service: Yes
Warranty: 1 Year
Accuracy: 1mm
Vertical Lines: 1
Horizontal Line: 1
Product Name: Resistivity Meter for Ves Surveying
Customization:
Gold Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
Groundwater Exploration
Usage
Water Exploration
Parameter
IP, Sp, Resistivity
Method
Ves
Voltage
1100V
Current
6A
Type
Digital Resistivity and IP Meter
Cable
Ab Wire and Mn Wire
Transport Package
Export Case
Specification
ISO9001
Trademark
GOLD
Origin
Chongqing, China
HS Code
9015800090
Production Capacity
100 Units/Month

Product Description

Geophysical Surveys Electrical Resistivity Induced Polarization Meter Subsurface Water Detection Instrument Geo VES Mineral Deposits Equipment

The Electrical Resistivity Induced Polarization (IP) meter is a geophysical instrument that measures the electrical properties of the subsurface. It provides valuable information about the resistivity and polarization characteristics of the rocks and soil layers, aiding in the identification of subsurface features, geological structures, and potential mineral deposits. The IP meter uses electrical currents and voltage measurements to assess variations in subsurface resistivity, which can indicate the presence of different geological formations and mineralization.

Geophysical Surveys Electrical Resistivity Induced Polarization Meter Subsurface Water Detection Instrument Geo Ves Mineral Deposits Equipment



Main Applications
By utilizing relevant parameters of apparent resistivity and induced polarization method, the instrument is widely used in many aspects including metal and non-metal mineral resources exploration, energy exploration, city geophysical exploration, railway and bridge engineering exploration, etc.

Geophysical Surveys Electrical Resistivity Induced Polarization Meter Subsurface Water Detection Instrument Geo Ves Mineral Deposits Equipment

Search for groundwater, solve the human and animal drinking water issue as well as industrial and agricultural water issue. Determine the hidden safety risk location in reservoir dam foundation and flood-control dyke, find faultage zone and collapse column, landslides, coal mining goaf, search for geothermal and other hydrological, engineering geological exploration.

Accessories made by our factory with 60-channel or 120-channel multiplex electrode switch, also can be used for multi-electrode resistivity survey system.


Geophysical Surveys Electrical Resistivity Induced Polarization Meter Subsurface Water Detection Instrument Geo Ves Mineral Deposits Equipment


Main Features:
Multiple functions in One Machine: The instrument has three functions including long lead IP instrument, master of 2D resistivity imaging system, and medium-power short lead transmitting.
Small-sized, Light in weight: The instrument integrates receiver and transmitter together in the same cabinet, which can be used for measurement via apparent resistivity method and induced polarization method.
Various Measurement Parameters: Instrument can be applied in direct measurement and indication of primary potential Vp, spontaneous potential Vsp, power supply current I, apparent resistivity Ro, apparent polarizability Ms, half-decay time Th, degree of decay D, integrated IP parameters Zp, and degree of deviation R.
More flexible and convenient operating mode: Adopt all-digital automatic measurement, can execute automatic compensation for spontaneous potential, drift and electrode polarization. Use large screen LCD display, can directly display the arrangement of nine electrodes; Directly input into pole arranging parameters with keyboard; Measuring resistivity curve apparent polarizability curve, half-decay curve, etc. Can be displayed directly when measurement of measuring point completes,
Data Interpretation is more convenient: The instrument can measure points on 4, 800 survey data for storage. Each measuring point has 22 data, with RS-232 serial interface, through appropriate software the stored data can be directly transfer to the computer for digital interpretation of various methods.
Beautiful Instrument Apparent, Strong Structured: The aluminum chassis effectively enhance the electromagnetic shielding; Adopts thin-film multi-layer sealed touch panel; Multiple over-voltage, over-current automatic protection are set for internal power supply part, allowing the instrument to be suitable for various types of field environment.

Geophysical Surveys Electrical Resistivity Induced Polarization Meter Subsurface Water Detection Instrument Geo Ves Mineral Deposits Equipment


 
Model & Name: WDJD-4 Multi-functional Direct Current ( Induced polarization ) Instrument
Max. Power Supply Voltage: 900V
Max. Power Supply Current: 5A
Voltage Measuring Range: ±6000mV
Voltage Measuring Accuracy: (Vp>10mV) ±5%, ±1 digit; (Vp<10mV) ±1%, ±1 digit
Current Measuring Range: 0.1mA~3000mA
Current Measuring Accuracy: Ip>10mA) ±5%, ±1 digit; (Ip<10mA) ±1%, ± digit
Interference Suppression on 50Hz Power Frequency Better than 80dB
SP Compensation Range: -1000mV~+1000mV
Instrument Input Impedance: ≥50MΩ
Operating Temperature: -10 °C ~50 °C , 95%Rh
Machine Size: 305×200×202mm

Geophysical Surveys Electrical Resistivity Induced Polarization Meter Subsurface Water Detection Instrument Geo Ves Mineral Deposits Equipment
Dc resistivity method is widely used to find the mine water-bearing abnormal body. The three-dimensional electrical method based on the two-dimensional graph can visually show the three-dimensional geometric model, and the pseudo-three-dimensional high-density electrical method can be used to detect the three-dimensional geological model. According to the continuity of geological structure between the two-dimensional planes, the measured data can be combined into a three-dimensional geological model. A relatively accurate bipolar detection device was selected, and the WGMD high-density electrical method system was adopted. The smooth constrained least squares inversion method was used to process the detection data repeatedly and iteratively, and the static correction technology was integrated to modify the detection data, so as to visualized Slicer in three dimensions The Dicer system obtains the slice data volume, delineates the approximate range of the abnormal low resistance body, and ensures the accurate judgment of the mine water cut abnormal body.

Geophysical Surveys Electrical Resistivity Induced Polarization Meter Subsurface Water Detection Instrument Geo Ves Mineral Deposits Equipment
Geophysical Surveys Electrical Resistivity Induced Polarization Meter Subsurface Water Detection Instrument Geo Ves Mineral Deposits Equipment
Geophysical Surveys Electrical Resistivity Induced Polarization Meter Subsurface Water Detection Instrument Geo Ves Mineral Deposits Equipment

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Year of Establishment
2009-09-11
Plant Area
377 square meters