• Geophysical 2D 3D Resistivity Tomography 2D IP Profiling Sounding Ves Exploration Equipment 2D and 3D Underground Resistivity Imaging System for Water Detection
  • Geophysical 2D 3D Resistivity Tomography 2D IP Profiling Sounding Ves Exploration Equipment 2D and 3D Underground Resistivity Imaging System for Water Detection
  • Geophysical 2D 3D Resistivity Tomography 2D IP Profiling Sounding Ves Exploration Equipment 2D and 3D Underground Resistivity Imaging System for Water Detection
  • Geophysical 2D 3D Resistivity Tomography 2D IP Profiling Sounding Ves Exploration Equipment 2D and 3D Underground Resistivity Imaging System for Water Detection
  • Geophysical 2D 3D Resistivity Tomography 2D IP Profiling Sounding Ves Exploration Equipment 2D and 3D Underground Resistivity Imaging System for Water Detection
  • Geophysical 2D 3D Resistivity Tomography 2D IP Profiling Sounding Ves Exploration Equipment 2D and 3D Underground Resistivity Imaging System for Water Detection

Geophysical 2D 3D Resistivity Tomography 2D IP Profiling Sounding Ves Exploration Equipment 2D and 3D Underground Resistivity Imaging System for Water Detection

After-sales Service: Yes
Warranty: 1 Year
Accuracy: 1mm
Vertical Lines: 1
Horizontal Line: 1
Product Name: 2D 3D Resistivity Imaging System
Customization:
Gold Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
WGMD
Tomograph
2D and 3D Resistivity
Channels
60channels, 120channels
Method
IP Sounding Equipment
Multi Electrodes Cable
30 Channel /PC
Transport Package
Export Case
Specification
ISO9001
Trademark
Gold
Origin
Chongqing
HS Code
9015800090
Production Capacity
100 Units/Month

Product Description

Geophysical 2D 3D Resistivity Tomography 2D IP Profiling Sounding Ves Exploration Equipment 2D and 3D Underground Resistivity Imaging System for Water Detection

Geophysical 2D 3D Resistivity Tomography 2D IP Profiling Sounding Ves Exploration Equipment 2D And 3D Underground Resistivity Imaging System For Water Detection
 
                                Geophysical 2D 3D Resistivity Tomography 2D IP Profiling Sounding Ves Exploration Equipment 2D and 3D Underground Resistivity Imaging System for Water Detection


WDA-1/WDA-1B is our latest all-purpose terrameter with 1D Res/IP sounding, 2D Res/IP imaging as well as 3D Res imaging function. It is widly apply for underground water inspection, energy resource prospecting, city geophysical exploration, metal and nonmetal mineral resources survey, geothermal field survey and so on.

Geophysical 2D 3D Resistivity Tomography 2D IP Profiling Sounding Ves Exploration Equipment 2D and 3D Underground Resistivity Imaging System for Water Detection



Application:
 
•   Underground water inspection  
•   Energy resource prospecting
•   City geophysical exploration  
•   Railway and bridge inspecting   
•   Metal and nonmetal mineral resources survey
•   Engineering geology
•   Geothermal field survey

Geophysical 2D 3D Resistivity Tomography 2D IP Profiling Sounding Ves Exploration Equipment 2D and 3D Underground Resistivity Imaging System for Water Detection

 
 Maximum power 7200W(VES),2400W(Imaging)
 Maximum voltage 1200V(VES),2400 peak-to-peak; 800V(Imaging), 1600 peak-to-peak
 Maximum current 6A(VES), 3A(Imaging)
 Power supply pulse width 1~60s, duty cycle is 1:1
Receiving
 Voltage ± 32V (24 bit A/D)
 Vp accuracy(before stacking) If Vp≥5mV, ±0.2% ±1LSB. If 0.1mV≤ Vp<5mV, ±1%±1LSB.
 Current 6A (24bit A/D)
 Ip accuracy(before stacking) If Ip≥ 5mA, ± 0.2% ±1LSB;If 0.1mA≤ Ip<5mA, then ± 1% ±1LSB..
 Apparent Polarizability     Accuracy ±1% ±1LSB

Geophysical 2D 3D Resistivity Tomography 2D IP Profiling Sounding Ves Exploration Equipment 2D and 3D Underground Resistivity Imaging System for Water DetectionBefore the project is carried out, it is necessary to find out the fault distribution in the working area. At present, 2D high density electrical method is mainly used for detection, and 3D high density electrical method is added for comparative analysis. In order to verify the effectiveness of 2D and 3D high-density electrical method in detecting faults and understand the response characteristics of faults, forward and reverse fault models were established. Forward modeling by finite element method and least square inversion were used to compare the differences of inversion results between different models. Finally, field examples were used for further analysis and verification. The results show that the high density electrical method is effective and accurate in detecting faults, but the detection effect of the reverse fault is obviously better than that of the normal fault. The 3D high density electrical method has abundant data and large inversion depth, and the results are closer to the theoretical model. The field measured data further verify the simulation results, and the conclusions obtained have certain guiding significance for fault detection, interpretation and analysis

Geophysical 2D 3D Resistivity Tomography 2D IP Profiling Sounding Ves Exploration Equipment 2D and 3D Underground Resistivity Imaging System for Water Detection

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Year of Establishment
2009-09-11
Plant Area
377 square meters