• Integrated Pile Tester Pile Driving Analyzer (PDA) and Pile Integrity Tester (PIT) for Geotechnical Suvey
  • Integrated Pile Tester Pile Driving Analyzer (PDA) and Pile Integrity Tester (PIT) for Geotechnical Suvey
  • Integrated Pile Tester Pile Driving Analyzer (PDA) and Pile Integrity Tester (PIT) for Geotechnical Suvey
  • Integrated Pile Tester Pile Driving Analyzer (PDA) and Pile Integrity Tester (PIT) for Geotechnical Suvey
  • Integrated Pile Tester Pile Driving Analyzer (PDA) and Pile Integrity Tester (PIT) for Geotechnical Suvey

Integrated Pile Tester Pile Driving Analyzer (PDA) and Pile Integrity Tester (PIT) for Geotechnical Suvey

After-sales Service: Yes
Warranty: equipment 2 Year, Sensor 1 Year
Max Diameter of Workpiece: >3200mm
Mass Scope of Workpiece: <900kg
Type: Pile Tester
Maxcapacity: >1000KN
Customization:
Gold Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GD-RHIB
Accuracy Grade
1
Load Way
Mechanical Load
Loading Method
Dynamic Load
Display
Digital
Control
Computer Control
Weight
0-100Kg
Power Source
AC220V
Oil Cylinder Position
Under
Magnification
30X
Field of View
1/30′
Shortest Focus Distance
1.5m
Reticle
Illuminated
Minimum Reading
1′′
Angle Accuracy
2′′
Single Prism
2000m/2500m/3000m
Reflector(60mmx60mm)
800m
Accuracy (Fine/Coarse/Tracking)
2mm±2ppm
Reflector-Less(Range)
350m
Transport Package
Carton Box
Specification
CE
Trademark
GOLD
Origin
China
HS Code
9015100
Production Capacity
1000 PCS Per Month

Product Description

Integrated Pile Tester Pile Driving Analyzer (PDA) and Pile Integrity Tester (PIT) for Geotechnical SuveyIntegrated Pile Tester Pile Driving Analyzer (PDA)and Pile Integrity Tester(PIT) for geotechnical suvey

 

Performance Parameters of Pile Driving Analyzer (PDA)and Pile Integrity Tester(PIT)
System
 
WINCE operating system; Industrial A8 processor.
System's operating frequency: 1G; memory: 512M
Sampling parameters
 
Number of channels
 
6 channels (2 high-strain acceleration channels, 2 strain channels, 1 low-strain acceleration channel, and 1 velocity channel
Number of AD bits
 
24 bits
Sampling interval
 
1.6us-52428μs, continuously adjustable at the spacing of 0.8us
Sampling length
 
1K, 2K
Amplification factor
 
X1, X2, X4, X8, automatic
Trigger mode
 
Channel trigger, steady state trigger
Bandwidth
 
High-strain acceleration: 1Hz-10kHz (<5%)
Low-strain acceleration: 1Hz-10kHz (<2%)  
Sampling precision
 
±2%
System noise
 
<0.2mV(rms)
Time error
 
<0.5%
Amplitude nonlinearity
 
<10%
Display features
 
Touch screen
 
Capacitive touch screen
Dimensions
 
8.4 inch display with optical bonding
Resolution  
 
800 x 600
Display mode
 
High-contrast concise display
Curve comparison
 
Automatic comparison in the same frame
Interface
 
Storage mode
 
Stored in memory, and automatically backed up in a SD card
Output interface
 
Two USB interfaces , Bluetooth interface, and USB flash drive interface for data transfer  
Input interface
 
Capacitive touch screen, standard USB keyboard and mouse
Power supply
 
Built-in battery
 
11.1V/7Ah rechargeable lithium battery working for more than 8 consecutive hours
External power supply
 
DC15V4A charger
Specifications
 
Volume and weight
 
255 x 190 x 50 (mm), 1.9Kg
Operating environment
 
Operating temperature
 
-10 ºC to 50 ºC
Operating humidity
 
<90%

What's Integrated Pile Tester can do?
The Pile Driving Analyzer (PDA) from Pile Dynamics is a very useful tool for estimating the geotechnical capacity and performance of driven and cast-in-place piles.

The test involves attaching accelerometer and strain transducers to the side of the test pile and impacting the top of the pile using a pile driving hammer or drop weight with sufficient energy.  The response from the sensors on the pile is recorded by the PDA and analysed later in the office with CAPWAP (CAse Pile Wave Analysis Program).



The Pile Integrity Tester (PIT) users the Sonic Echo or Pulse Echo method to conduct low strain pile integrity testing. PIT is a non-destructive testing method used on concrete piles to detect potential defects such as cracks, necking, soil inclusions and voids.

A wireless accelerometer is attached to the top of the prepared pile and impacted with a small hand-held hammer.  The accelerometer monitors the impact and resulting reflections of the compression wave travelling through the pile.  The results are evaluated in the field and later in the office using PIT-W software.

Key Output Results about Integrated Pile Tester 
maximum force applied to the pile head;
maximum pile head velocity;
maximum energy imparted to the pile;
maximum displacement of the pile head;
pile cap estimate;
maximum compressive stress in the pile;
maximum tensile stress in the pile;
estimated final pile set.
Pile Integrity Factor

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Year of Establishment
2009-09-11
Plant Area
377 square meters