Underground Water Detection, Ground Water Detector, geophysical resistivity meter, geophysical survey equipment and water survey equipment detector
Application:
1 Widely used for high-resolution research, tomography and monitoring applications.
2 Coal mining gobs, caves of Custer area, geological disasters survey like landslides other geological disasters.
3 High resolution engineering geological exploration like factory foundations, highways, bridges, railways, civil engineering, hydrology, engineering, environmental.
4 For landslides and other geological disaster exploration.
5 Metal and non-metallic mineral resources exploration and geothermal exploration.
System Composition
One DAZ-6A multi-functional DC resistivity instrument as the survey and control unit in the system, equipped with a DUK-2A type 60-channel or 120-channel multiplex electrode switch manufactured by our factory, and cables, electrodes and other related accessories, together to form the resistivity imaging system.
|
Model & Name:
|
DZD-6A Multi-functional Direct Current ( Induced polarization ) Instrument
|
Max. Power Supply Voltage:
|
900V
|
Max. Power Supply Current:
|
5A
|
Voltage Measuring Range:
|
±6000mV
|
Voltage Measuring Accuracy:
|
(Vp>10mV) ±5%, ±1 digit; (Vp<10mV) ±1%, ±1 digit
|
Current Measuring Range:
|
0~5000mA
|
Measuring Current Resolution:
|
0.01mA
|
Current Measuring Accuracy:
|
Ip>10mA) ±5%, ±1 digit; (Ip<10mA) ±1%, ± 1 digit
|
Interference Suppression on 50Hz Power Frequency
|
Better than 80dB
|
Measured Apparent Polarizability Accuracy :
|
±1%, ±1 digit
|
Instrument Input Impedance:
|
≥50MΩ
|
Power Supply Pulse Width:
|
1~60s
|
Operating Temperature:
|
-10 °C ~50 °C , 95%Rh
|
Size:
|
305×200×202m
|
2. DUK-2A Multiplex Electrode Converter
Model & Name:
|
DUK-2A Multi-electrode Converter
|
Conversion Electrodes :
|
60 channels or 120 channels
|
Supported manual configuration :
|
1, Schlumberger 2, Dipole-Dipole, Combined Profiles, Differential, Pole-Pole, Triple-Pole Rolling,
|
Operating Mode :
|
16-key keypad with 90 character LCD display combines to form man-machine dialogue operation.
|
Maximum Allowable Current :
|
2A
|
Maximum Withstand Voltage :
|
500V DC
|
Insulating Property :
|
500MΩ
|
Electroshock Break-over Resistance :
|
smaller than 0.1Ω
|
Power Consumption
|
50 mA (Standby)
|
Power Supply :
|
1# Dry Cell (or rechargeable battery with the same specification) 8pcs.
|
Weight :
|
7 kg (60 channels), 7.5kg (120 channels)
|
Operating Temperature:
|
-10 °C ~50 °C , 95%Rh
|
Size:
|
305×200×202mm (60 channels)
324×200×245mm (120 channels)
|
Underground Water Detection, Ground Water Detector, geophysical resistivity meter, geophysical survey equipment and water survey equipment detector
|