Customization: | Available |
---|---|
Accuracy: | <1mm |
Horizontal Line: | 1 |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Sensor Type | Symmetrical Configuration (3 Component), Orthogonal Output |
Feedback | Force balance with capacitive transducer |
Bandwidth | 0.0083 (120 seconds) - 80 Hz (Flat velocity response) 0.0167 (60 seconds) - 80 Hz (Flat velocity response) |
Dynamic Range | >140dB (0.01 -0.05Hz); >160 dB (1-10 Hz) |
Self-Noise | Below NLNM from 40 seconds to 10 Hz |
Clip Level | >10 mm/s (@1 Hz) |
Nominal Sensitivity | 2000 V/m/s s ±0.5% (see supplied test sheet for precise value) |
Full Scale Output | 40 Volts Peak-Peak (Differential Output) |
Output Impedance | <100 Ohms |
Parasitic Resonances | >160 Hz |
Cross Axis Coupling | <1% |
Linearity | <-60 dB |
Total Harmonic Distortion |
<-60 dB |
Calibration Constant | 10 m/s2/A (nominal) |
Calibration Input | Calibration current on 3 components simultaneously |
Calibration Enable Capability | Active Low on Pin L to stay enable |
Cal Coil | Single Cal signal input, isolated until cal enable line activated |
Mass Position Outputs | ±10 V |
POWER | |
Input Voltage | 9-18 VDC |
Consumption | <0.7 Watts |
Protection | Over-voltage, Reverse-voltage, & surge protection |