Customization: | Available |
---|---|
Accuracy: | 1mm |
Horizontal Line: | 1 |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Features:
Electrical Motor Logging Winch: The Geophysical Logging Winch is equipped with a powerful electrical motor that drives the winch drum. The motor provides consistent and controlled movement of the logging cable, ensuring smooth deployment and retrieval of the logging tools.
Vehicle Mounted Winch: The winch can be mounted on a vehicle, making it portable and easily transportable to various field locations. This feature allows for flexibility in accessing different boreholes and conducting geophysical logging surveys in diverse terrains.
Land Wireline Winch: The winch operates using a wireline system, where the logging cable is spooled onto a drum. The cable is strong and durable, capable of withstanding the stresses of deep borehole logging. The wireline winch system ensures reliable and efficient data transmission between the downhole tools and the surface equipment.
Borehole Depth Range: The Geophysical Logging Winch is designed to handle boreholes ranging from 100 meters to 3000 meters in depth. It has the capacity to deploy and retrieve logging equipment through these depths, enabling comprehensive subsurface data collection in a wide range of applications.
Borehole Downhole Logging: The winch is primarily used for downhole logging, where various logging tools are lowered into the borehole to measure and record different geophysical properties. These properties may include resistivity, gamma radiation, fluid conductivity, temperature, and sonic velocity, among others. The winch ensures precise control and stability during the logging process.
Automatic Winch Controller |
(1) Speed range: 0~30 meter/minute; Automatic/Manual total two controlling modes; |
(2) Constant speed range: 0.5~20 meter/minute, error is ±5%; |
(3) Depth range: 0~9999.99 meters, error ≤±0.4%; |
(4) Controlling mode: Automatic, manual, and check; |
(5) Controlling direction: Up, and down; |
(6) Measurement mode: fixed point measurement, and continuous measurement; |
(7) Working temperature: -10~55 °C; |
(8) Power supply: AC 220V±10%, 50 Hz |