Customization: | Available |
---|---|
After-sales Service: | 24h Online |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Features:
* High accuracy and repeatability: 0.05ppm
* Non-contact measurement: Won't cause damage to samples and can carry out remote measurement
* Real-time measurement: Fast response to reflect changes for measured objects and give result
* Multi-functional: Can measure length, angle, surface roughness, etc. By changing different mirrors and detectors, different measurement functions can be realized
* Great stability: Utilizes the coherent nature of laser light to effectively suppress the effects of external interference
Application:
* Measure the straightness and parallelism of machine tool guideway
* Measure the flatness and perpendicularity of machine tool table
* Measurement of concentricity and axial perpendicularity of machine tool spindle
* Measure the relative position and dimensional relationship between various parts of the machine tool, so as to detect and correct the assembly error of the machine tool
GD-6000 Machine tool calibration laser interferometer | ||
No. | Item | Parameter |
1 | Frequency stabilization accuracy | 0.05ppm |
2 | Dynamic acquisition frequency | 50kHz |
3 | Warm-up time | ≤6 min |
4 | Working temperature range | 0~40ºC |
5 | Storage temperature range | -20~70ºC |
6 | Humidity | 0~95%RH |
7 | Linear measurement distance | 0~80m |
8 | Linear measurement accuracy | 0.5ppm |
9 | Angle axial range | 0~15m |
10 | Angle measurement accuracy | ±0.02%R+0.1+0.024M″ |
11 | Flatness axial range | 0~15m |
12 | Flatness measurement accuracy | ±0.2%R+0.02M2μm (R: the display value, unit: μm; M:the measuring distance, unit: m) |
13 | Straightness axial range | short distance:0.1~4.0m; long distance:1.0~20.0m |
14 | Straightness measurement accuracy | short distance: ±0.5+0.25%R+0.15M2 μm; long distance ±5.0+2.5%R+0.015M2μm |
15 | Verticality axial range | Short distance:0.1~3.0m; long distance1.0~15.0m |
16 | Verticality measurement accuracy | short distance ±2.5+0.25%R+0.8Mμm/m; long distance ±2.5+2.5%R+0.08Mμm/m |
17 | Angle measurement range | ±10° |
18 | Power supply | 100~240V AC |
19 | Standard configuration weight | 18kg |
20 | Dimension | 613*460*230mm |